Page 76 - 20250602 EEA QM Edition 6.0
P. 76

Quality Requirements Edition 6.0                                                                                  European Enamel Association




            7.20.3 Quality requirements

            Test method               Requirement                                          Remarks                            Frequency
            3.5 visual assessment     Inside surface: discontinuity free (see 4.12)                                           in production 100 %
                                      Outside surface: max. 3 defects/m  with a max. defect size of
                                                                 2
                                      1mm in diameter (*)
            3.9.3 hardness            hardness Mohs ≥ 5                                    on test sheets                     when taking into production a sig.diff.
                                                                                                                              enamel recipe, but at least 1 x a month
            4.3 thickness enamel coating  Outside surface: 330 ± 170µm                                                        In accordance with EN ISO 2859-1
                                      Inside surface: 360 ± 100µm
                                      except for roofs of thermophilic/pasteurisation digesters, industrial
                                      tanks with aeration processes and aggressive chemical industrial
                                      effluent / high temperature applications:
                                      Inside surface: 400 ± 100µm
             4.4 cold citric acid     class AA                                             EN ISO 28706-1/9                   in production 1 x per month
                cold sulphuric acid   class A+ min., except for roofs of thermophilic/pasteurisation   EN ISO 28706-1/10      in production 1 x per month
                                      digesters, industrial tanks with aeration processes and aggressive
                                      chemical industrial effluent / high temperature applications: class
                                      AA required
                cold hydrochloric acid   class A min., except for roofs of thermophilic/pasteurisation   EN ISO 28706-1/11 10% solution 15min.  in production 1 x per month
                                      digesters, industrial tanks with aeration processes and aggressive
                                      chemical industrial effluent / high temperature applications: class
                                      AA required
            4.5 boiling citric acid   weight loss: max. 1,5 g/m  after 2.5 hours           EN ISO 28706-2/11                  when taking into production a sig.diff.
                                                          2
                                      except for roofs of thermophilic/pasteurisation digesters and   on test sheets conform to EN ISO 28764  enamel recipe, but at least 1 x a year
                                      industrial tanks with aeration processes: max. 0,75 g/m²
                                      except for aggressive chemical industrial effluent / high
                                      temperature applications: max. 0,5 g/m²
            4.6 boiling water         liquid phase max. weight loss: 2,5 g/m  after 48 hrs. except for   EN ISO 28706-2/14    when taking into production a sig.diff.
                                                                    2
                                      aggressive chemical industrial effluent / high temperature   on test sheets conform to EN ISO 28764  enamel recipe, but at least 1 x a year
                                      applications: max. 1,0 g/m²
                                                                     2
                                      vapour phase max. weight loss: 7,5 g/m  after 48 hrs.
                                      except for roofs of thermophilic/pasteurisation digesters and
                                      industrial tanks with aeration processes: max. 5,0 g/m²
                                      except for aggressive chemical industrial effluent / high
                                      temperature applications: max. 2,5 g/m²
            (*)  When agreed between parties, it is permissible to rectify defects on outside surfaces using an approved material and process, at the condition rectified defects have a